-40%
EMTEST OCS 500N6.4 + VCS 500N8 + CNI503 (CNV 503S5)
$ 44880
- Description
- Size Guide
Description
EMTEST OCS500N6.4 + VCS500N8 + CNI503 (CNV503S5)OCS500N6.4 : Oscillatory Wave Generator
OCS 500N6 - Compact tester for Ringwave and Damped Oscillatory Waves The OCS 500N6 includes test capabilities for ringwave up to 6kV (as per EN/IEC 61000-4-12) and the damped oscillatory waves at 100 kHz and 1 MHz up to 3 kV (as per EN/IEC 61000-4-18). The Ringwave is a non-repetitive damped oscillatory transient occurring in low-voltage power, control and signal lines supplied by public and non-public networks. Damped Oscillatory Waves are repetitive transients mainly occurring in power, control and signal cables installed in high voltage and medium voltage stations. The OCS 500N6 can also be used to perform magnetic field tests as required in EN/IEC 61000-4-10 using a magnetic field coil such as the MS 100N.
Standalone test generator
Includes Ringwave up to 6 kV
Includes Damped Oscillator Waves up to 3 kV
Built-in CDN, single phase or three-phase up to 100 A
Front panel operation
Standard Test routines
USB and GPIB interfaces
VCS500N8 :
8KV COMBINATION WAVE SIMULATOR
Combination Wave Simulator Surge pulses occur due to direct or indirect lightning strokes to an external (outdoor) circuit. This leads to currents or electromagnetic fields causing high voltage or current transients. Another source for surge pulses are switching transients originating from switching disturbances and systems faults. Due to the characteristic of the phenomenon nearly every electrical and electronical device may suffer from such lightning events which justifies the necessity of surge tests being widely performed. Surge voltage can reach several thousands of volts and surge current is seen to reach several thousands of amps.
Surge voltage up to 8kV
Surge current up to 4kA
Voltage/current monitors
Built-in CDN 1-phase or 3-phase up to 3 x 690V and 32A
Interlock
Warning lamp control
Manual operation
USB (optical link) and GPIB interface
CNI503 (
CNV503S5)
:
3-Phase Coupling Decoupling Network
he three-phase coupling/decoupling networks of the CNI 503x series are used to couple EFT/Burst pulses and Surge pulses on DC-lines or to three-phase (4-wire or 5-wire supply lines) mains supply systems for voltages up to 1,000VDC / 3x690VAC. This includes the more and more common testing of inverters used in the area of renewable energies (e.g. photovoltaic systems, wind power stations, electric cars).Within the range of EM TEST coupling/decoupling networks we offer different models for test voltages from 5kV up to 10kV with DUT currents of 16A, 32A, 63A, 100A and 200A for the various test requirements and equipment configuration.Testing of electronic modules with EFT/burst, 1.2/50µs Surge or Ring Wave pulses up to 10kV, 5kA The CNI 503 couples the surge and burst pulses from the impulses generators UCS 500Nx to a three phase test object (coupling as per. IEC or ANSI standard). The CNI 503 is controlled from EM Test transient generator of the Series 500 (UCS 500Nx, VCS 500Nx, EFT 500Nx).Burst, Surge and Ringwave Pulse as per.
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-12
ANSI
Terms & Conditions
A. Warranty
We provide 30 days ROR (Right of Refusal).
B. Payment
When customers purchase any equipment from Nubicom, customer has to pay 100% in advance.
C. International Shipping
We are supporting any global forwarders such as
FedEX
, DHL and UPS. Nubicom can help to ship the equipment at buyer's shipping preference. Otherwise, we can offer the estimated international shipping cost to your destination upon request.
Thank you for visiting
Nubicom’s
eBay Store!